Intelligent integrated micro module>Monitoring Mainframe
Host features (1) using Cortex-A8 CPU chip, 1G memory, 8G Flash storage. (2) highly integrated monitoring software and hardware products, with 10 serial ports: 2 RS232/RS485 compatible serial ports, 8 RS485 serial ports, 8 analog inputs 8 dry contact inputs, 4 dry contact outputs, 4 special switch inputs, can be connected to smoke, door magnetic, water flooding, infrared, etc., 2-way battery pack end voltage and midpoint voltage, 2 RJ45 IP network ports, 1 USB port. (3) Dual 220V AC power supply. (4) support ZigBee wireless acquisition expansion, support wireless ZigBee temperature and humidity, wireless ZigBee dry contact sensors and wireless ZigBee serial intelligent devices. (5) can support 4G wireless transmission expansion plug-in module. (6) can be added according to the needs of the project configuration SMS alarm module;monitoring the host can be fully access to the monitoring module. (7) monitoring host can fully access the intelligent equipment in the server room, built-in more than 1200 kinds of UPS, air conditioning, power distribution cabinets, oil machines, meters and other intelligent equipment protocols, plug and play. (8) the bottom hardware optoelectronic isolation, strong anti-interference, with lightning protection function. Monitoring host system (1) embedded Linux monitoring platform Nurse, simple installation and debugging, no need to allocate another server, suitable for small and medium-sized server rooms or modular server rooms low-cost rapid deployment. (2) Provide configuration tools, support 2D and 3D full configuration interface. (3) Support for electronic maps, server room floor plans, power distribution diagrams and wiring diagrams. (4) Support online configuration modification function. (5) automatic slide show function of 3D configuration diagram of the server room, without mouse click operation, the software automatically plays the real-time status of each room. (6) support automatic calculation and real-time display of the PUE index of the server room (7) support wireless temperature field cloud map, the system through the wireless ZigBee terminal equipment and temperature probe, real-time monitoring of the temperature field of the server room, can directly get the temperature field data and changes in each cabinet in the server room, draw the temperature field cloud map of the entire server room, master the cooling effect of the server room, so as to guide the layout and maintenance of the server room air conditioning work, to ensure the reliable operation of IT equipment. (8) Support SNMP external interface protocol. |